Prime Output at Rated Speed 16 hp (12 kW)

Generator Set
  • Heavy duty generator system designed for prime power operation in rental, construction and special events applications.
  • Generator system features a heavy-duty, drag-able skid base, and can be easily equipped with an integrated running gear system for mobile applications.
Unit of Measure

Reference Conditions

Maximum Ambient Temperature1 N/A 104 ºF40 ºC

Maximum Relative Humidity

N/A 100 %

Maximum Altitude

N/A ft, m

Minimum Starting Temperature (Standard)

N/A 10 ºF-12 ºC

Minimum Starting Temperature (with Cold Start Option)

N/A -4 ºF-20 ºC

Engine Data

Engine Manufacturer

N/A IR / Mitsubishi

Model Number

N/A S3L2-W262

Prime Output at Rated Speed

N/A 16 hp12 kW

Standby Output at Rated Speed

N/A 17 hp13 kW

Engine Type

N/A Inline Four Cycle

Engine Control

N/A Mechanical

Emissions Certification

N/A Tier II

Number of Cylinders

N/A 3

Aspiration

N/A Natural

Bore

N/A 79 mm3.1 in

Stroke

N/A 92 mm3.6 in

Displacement

N/A 79 in³1.3 L

Compression Ratio

N/A 22:01

Governor Type

N/A Mechanical

Speed Regulation Accuracy (Steady State)

N/A ±0.25 %

Single Step Load Acceptance

N/A 100 %

Cooling System

N/A Water / Glycol

Charging Alternator Output

N/A 50 A

DC System Voltage

N/A 12 V

Battery Output

N/A 520 CCA

Oil Sump Capacity

N/A 1 gal3.8 L

Cooling System Capacity

N/A 2 gal7.6 L

Fuel Cell Capacity (Usable Capacity - Level Operation)

N/A 27 gal102 L

Fuel Consumption at Prime Power Rating at 25% Load

N/A 112.5 Runtime 0.24 gal/h0.9 L/h

Fuel Consumption at Prime Power Rating at 50% Load

N/A 56.3 Runtime 0.5 gal/h1.8 L/h

Fuel Consumption at Prime Power Rating at 75% Load

N/A 37.7 Runtime 0.7 gal/h2.7 L/h

Fuel Consumption at Prime Power Rating at 100% Load

N/A 28.2 Runtime 1 gal/h3.6 L/h

Alternator Data

Alternator Manufacturer

N/A Leroy Somer

Alternator Model

N/A LSA 422 S4

Alternator Type

N/A Four Pole, Revolving Field

Number of Leads

N/A 12

Insulation Class

N/A H

Frequency

N/A 60 Hz

Available Voltages - Single Phase

N/A 120, 240 V

Excitation Method

N/A AREP

Voltage Regulation Accuracy (Steady State)

N/A ±0.5 %

Total Harmonic Distortion (THD) at No Load

N/A < 5%

Telephone Influence Factor (TIF)

N/A < 50

Running Gear

Running Gear

N/A To 49CFR571 requirements

Configuration

N/A Single axle

Suspension

N/A Torsion bar
Standard Brake System Configuration2 N/A Brakeless

Tires

N/A ST175/80D13

Wheels

N/A 15 × 5.5 in (381 × 140 mm), 5 lug on 4.5 in (114 mm) bolt circle

Lighting and Reflectors

N/A Meets FMVSS 571.108 requirements

Electrical Connection to Towing Vehicle

N/A Six pole round plug

Standard Coupling Connection

N/A 3 in (76 mm) Pintle Eye (2 in (51 mm) Ball Coupler Optional)

Optional Coupling Connections

N/A 2 in (51 mm) Ball Coupler or 2-5/16 in (59 mm) Ball Coupler Optional
Safety Chains3 N/A 2 × 5/16 in8 mm
Jack Stand Configuration4 N/A 2000 lb907 kg

Sound Level at 23 ft (7m) and 100% Load

N/A 66 dBA

Weight and Dimensions with Running Gear

Length for Weight and Dimensions with Running Gear

N/A 123.5 in3317 mm

Width for Weight and Dimensions with Running Gear

N/A 55.5 in1410 mm

Height for Weight and Dimensions with Running Gear

N/A 55.1 in1400 mm

Weight (Shipping) for Weight and Dimensions with Running Gear

N/A 1557 lb706 kg

Weight (Ready to Run) for Weight and Dimensions with Running Gear

N/A 1747 lb792 kg

Weight and Dimensions Less Running Gear

Length for Weight and Dimensions Less Running Gear

N/A 61.7 in1567 mm

Width for Weight and Dimensions Less Running Gear

N/A 33.5 in851 mm

Height for Weight and Dimensions Less Running Gear

N/A 44 in1118 mm

Weight (Shipping) for Weight and Dimensions Less Running Gear

N/A 1341 lb608 kg

Weight (Ready to Run) for Weight and Dimensions Less Running Gear

N/A 1531 lb694 kg

Certification

N/A CSA certified for electrical equipment per C22.2, No. 14

Features

N/A Engine

  • Industrial, heavy-duty diesel engine is EPA emissions certified to current Tier II requirements.
  • Oversized cooling system rated for high ambient operation.
  • All filters and maintenance points are easily accessed enhancing serviceability.
Generator
  • AREP brushless excitation provides powerful motor starting kVA and is isolated from harmonicinduced waveform distortion.
  • Class H insulation for ultimate resistance to high temperature and humidity.
  • Capable of supporting up to 300% overload for up to 10 seconds.
  • R438 voltage regulator provides superior voltage stability and transient recovery.
  • Single, sealed-for-life bearing ensures long maintenance-free performance.
Power Connections
  • All controls and connection points are grouped at the rear of the unit for safety and operator convenience.
  • Convenience receptacles included standard, each protected by individual branch circuit breakers (see chart below for configuration).
Fuel System and Environmental Containment
  • Single wall steel fuel tank is mounted within the skid base, providing double wall protection and 110% environmental containment of all fluids.
  • The fuel filler is lockable and is located within the containment basin, minimizing possible spillage.
Enclosure
  • The heavy duty enclosure provides weather protection of components and provides sound attenuation for use in noise sensitive areas.
  • The enclosure is coated with a 13 stage paint process including E-coat primer for superior corrosion resistance and a high gloss powder paint for long life.
  • The engine generator assembly is mounted on fail-safe vibration isolators.
  • Wide opening side access doors are hinged, providing easy access and are equipped with recessed, pad-lockable handles.
  • Package is equipped with a center-point lifting eye for safe, well-balanced hoisting.
  • Mobile units are equipped with a fold-up drawbar which can maximize shipping configuration and reduce package footprint.
Warranty
  • G10 is covered by a comprehensive limited warranty:
    • Package: 1 year / 2000 hours
    • Engine: 2 years / 4000 hours
    • Alternator: 2 years / 4000 hours
    • Extended warranty options are available

Control Panel Features

N/A

  • Fuel tank level gauge (mounted on fuel tank)

  • 1 For operation outside of these reference conditions, contact us
  • 2 Electric Brakes optional
  • 3 Chains with slip hooks and safety latches
  • 4 Capacity, top wind with sand shoe, trunion mounted