Print Back
Construction:
  • Ribbed thin-wall cast iron crankcase for added strength and durability
  • Internal crankcase breather for reduced emissions
  • Extra large bearing surfaces for low bearing loads and long life
Unit of Measure

Specifications

Brands

Mitsubishi

Engine Cycle

4-Stroke

Cooling System

Water-Cooled

Engine Type

Turbocharged Diesel

Bore

94 mm

Stroke

120 mm

Cylinders

4

Cylinder Arrangement

Inline

Total Displacement

3.331 L

Combustion System

Direct Injection

Dry Weight

250 kg551 lb

Electric Starting System Voltage

12 V

Fuel Oil

Diesel Fuel Oil (ASTM No. 2-D)

Emission Standards

Tier3

Oil Capacity

2.64 gal10 L

Power Unit

Continuous Output Power Rating at 1500 rpm

57.0 hp42.5 kW

Continuous Output Power Rating at 1800 rpm

67.0 hp50.0 kW

Continuous Output Power Rating at 2000 rpm

72.4 hp54.0 kW

Continuous Output Power Rating at 2200 rpm

76.7 hp57.2 kW

Continuous Output Power Rating at 2500 rpm

83.1 hp62.0 kW

Generator

Prime Power Rating Output at 60 Hz and at 1800 rpm

57.3 hp42.7 kW

Stand-by Rating Output at 60 Hz and at 1800 rpm

60.3 hp45.0 kW

Lubrication

Lubrication

  • Designed to run at up to 25 degrees of inclination and includes a full flow spin-on cartridge filter
  • Forced circulation by trochoid gear pump

Fuel and Combustion Systems

Fuel and Combustion Systems

Bosch style fuel injection pump

Mounting

Mounting

  • Standard crankcase side mounting pads for flexible mounting arrangements
  • Rear engine support available from side mounting pads on SAE 3 housing

Cooling

Cooling

  • Forced circulation by centrifugal pump
  • Cooling packages available for ambient temperatures up to 108 ºF (42 ºC)
  • Cooling Fan (Std. Eqt.) : Variable Speed (VS) - Suction
  • Cooling Fan (Std. Eqt.) : Generator Drive (GD) - Pusher

Electrical System

Starter Voltage

12 V

Starter Power

2.2 kW

Alternator Voltage

12 V

Alternator Power with Integral Regulator

50 A

Glow Plug Voltage

12 V

Switch

High Water Temperature Low Oil Pressure

Stop Solenoid

12 V, energized to run (ETR) solenoid

Governing

Governing

Mechanical governing is provided for either variable or constant speeds

Drives

Drives

  • SAE 3 flywheel housing and 11.5 in flywheel (GD and VS models)
  • Rotation direction: counter-clockwise, facing the flywheel
  • Side PTO drives are available for mounting at the gear end